CMD TECHNOLOGY, INC.

CRD-5400-001, CRD-5400-002, CRD-5400-003

Card Type               Hard drive controller card
Processor               RISC
Maximum Onboard Memory  256MB DRAM
Hard Drives supported   Fourteen Fast SCSI devices (5400-001)

                        Fourteen Fast/Wide SCSI devices (5400-002)

                        Fourteen Fast/Wide SCSI devices (5400-003)
Floppy drives supported None
Data Bus                Fast/Wide SCSI (5400-001)

                        Fast/Wide SCSI (5400-002)

                        Fast/Wide/Differential SCSI (5400-003)
Form-factor             5.25 inch
RAID levels supported   0, 1, 0+1, 4 and 5, JBOD

[Image]

                                CONNECTIONS

       Function          Location           Function           Location

  50/68-pin SCSI            CN1        UART/monitor              CN7
  connector - channel                  connector
  1

  50/68-pin SCSI            CN2        Environmental             CN8
  connector -                          control system -
                                       not used
  channel 0

  68-pin SCSI               CN3        Battery connector         CN9
  connector - host
  channel

  External                  CN4        Power connector           CN10
  temperature sensor
  and UPS signals

  Alarm - external          CN5        Fan power connector        W8

  Test connector            CN6

  Note: Connectors CN1 and CN2 differ on each model. See header.

            DRAM CONFIGURATION

    Size         Bank 0         Bank 1

     4MB       (1) 1 x 36        None

     8MB       (1) 1 x 36     (1) 1 x 36

     8MB       (1) 2 x 36        None

    16MB       (1) 2 x 36     (1) 2 x 36

    16MB       (1) 4 x 36        None

    32MB       (1) 4 x 36     (1) 4 x 36

    32MB       (1) 8 x 36        None

    64MB       (1) 8 x 36     (1) 8 x 36

    64MB       (1) 16 x 36       None

    128MB      (1) 16 x 36    (1) 16 x 36

    128MB      (1) 32 x 36       None

    256MB      (1) 32 x 36    (1) 32 x 36

                       MISCELLANEOUS TECHNICAL NOTES

  To prevent power interruptions affecting data held in controllers
  cache, it is recommended that you connect an attached battery back-up
  or an uninterruptible power supply. Also, terminating drive buses by
  installing on-board resistors is not recommended because the end drive
  on the bus cannot be removed during a "hot swap" without leaving the
  bus unterminated.