ARCHIVE CORPORATION

SC499

Card Type              Tape drive controller
Chip Set               Unidentified
Maximum Onboard Memory Unidentified
I/O Options            1/4 inch cartridge tape drive
Tape Format            QIC 11, QIC 24
Data Bus               8-bit ISA
Card Size              Full-length, full-height

[Image]

                                CONNECTIONS

          Function            Label            Function            Label

  Tape drive connector -       J2      Tape drive connector -       J3
  external                             internal

                        USER CONFIGURABLE SETTINGS

                   Function                      Label        Position

     Factory configured - do not alter            C            Open

     Track selection - 9                          Y           Closed

      Track selection - 4                          Y            Open

     Tape format - QIC-24                        CC           Closed

      Tape format - QIC-11                        CC            Open

     Tape speed 90 IPS                           DD            Open

      For Manufacturing test only                 DD           Closed

     Factory configured - do not alter           FF            Open

     Factory configured - do not alter           HH            Open

     Power-on test enabled                       KK           Closed

      Power-on test disabled                      KK            Open

     Factory configured - do not alter           NN            Open

     Ready interrupt enabled                     RR            Open

      Ready interrupt disabled                    RR           Closed

                           DMA CHANNEL SELECTION

  Channel       JP6       JP5       JP4        JP3       JP2       JP1

       1     Closed      Open      Open     Closed     Open       Open

        2      Open      Closed     Open      Open     Closed      Open

        3      Open       Open     Closed     Open      Open      Closed

                        BASE I/O ADDRESS SELECTION

   Setting       A3      A4       A5       A6      A7       A8       A9

        0h      Off      Off      Off     Off      Off     Off      Off

        8h       On      Off      Off     Off      Off     Off      Off

       10h      Off      On       Off     Off      Off     Off      Off

       18h       On      On       Off     Off      Off     Off      Off

       20h      Off      Off      On      Off      Off     Off      Off

      200h     Off      Off      Off     Off      Off     Off       On

       3D8h      On      On       Off      On      On       On       On

       3E0h     Off      Off      On       On      On       On       On

       3E8h      On      Off      On       On      On       On       On

       3F0h     Off      On       On       On      On       On       On

       3F8h      On      On       On       On      On       On       On

                                   Note:

  A total of 128 base address settings are available. The jumpers are a
  binary representation of the decimal memory addresses. Jumper A9 is the
  Most Significant Bit and jumper A3 is the Least Significant Bit. The
  jumpers have the following decimal values: A9=512, A8=256, A7=128,
  A6=64, A5=32, A4=16, A3=8. Turn off the jumpers and add the values of
  the jumpers and convert to hexadecimal to obtain the correct memory
  address. (Off=0, On=1)

                            INTERRUPT SELECTION

     IRQ        JP7        JP8       JP9      JP10      JP11       JP12

      IRQ2      Open      Open      Open      Open      Open      Closed

     IRQ3      Open      Open      Open      Open     Closed      Open

      IRQ4      Open      Open      Open     Closed     Open       Open

      IRQ5      Open      Open     Closed     Open      Open       Open

      IRQ6      Open     Closed     Open      Open      Open       Open

      IRQ7     Closed     Open      Open      Open      Open       Open

                             DIAGNOSTIC LED(S)

  Note: The function of the LEDs is unidentified, however on power up or
  reset all LEDs will light up. When the reset or self test is completed
  the LEDs will turn off.