ACCTON TECHNOLOGY CORPORATION

Etherpair-NE2 (EN1622)

NIC Type      Ethernet
Transfer Rate 10Mbps
Data Bus      16-bit MCA
Topology      Linear bus

              Star
Wiring Type   Unshielded twisted pair

              AUI transceiver via DB-15 port
Boot ROM      Available

[Image]

                      SIGNAL QUALITY ERROR (SQE) TEST

                 Setting                                JP1

                  Disabled                            Closed

                   Enabled                              Open

  Note: Signal Quality Error (SQE) is a test of the collision circuitry
  and path.

                            LINK INTEGRITY TEST

                 Setting                                JP2

                  Enabled                             Closed

                   Disabled                             Open

  Note: Link Integrity is only used with 10Base-T wiring. When using an
  AUI transceiver, the test should be disabled.

                                CABLE TYPE

                   Type                              JP3A - JP3I

           Unshielded twisted pair               Pins 1 & 2 Closed

         AUI transceiver via DB-15 port           Pins 2 & 3 Closed

                             DIAGNOSTIC LED(S)

   Led      Color          Link         Status            Condition
                        Integrity

   LED1      Red           N/A           Off            No collisions
                                                     detected on network

   LED1      Red           N/A         Blinking     Collision detected on
                                                           network

   LED2     Green          N/A            On            Data is being
                                                       received power

   LED2     Green          N/A         Blinking         Data is being
                                                         transmitted

   LED3      Red           N/A           Off         Normal operational

   LED3      Red           N/A            On          Card is jabbering,
                                                         transmitting
                                                        continuously

   LED4     Green        Enabled          On         Twisted pair network
                                                     connection is good

   LED4     Green        Enabled         Off         Twisted pair network
                                                    connection is broken

   LED4     Green        Enabled       Blinking         Data is being
                                                          received

   LED4     Green       Disabled          On            Data is being
                                                       received power

   LED4     Green       Disabled         Off          Data is not being
                                                       received power

   LED4     Green       Disabled       Blinking         Data is being
                                                          received

  Note: The condition displayed by LED4 depends on the setting of the
  link integrity JP2.