EDIMAX COMPUTER COMPANY

AL-3353/AL-3354

NIC Type      ARCnet
Transfer Rate 2.5Mbps
Data Bus      16-bit ISA
Topology      Star

              Linear Bus
Wiring Type   RG-62A/U 93ohm coaxial

              Unshielded twisted pair
Boot ROM      Available

[Image]

                              NODE ID ADDRESS

  Node   SW1/1    SW1/2   SW1/3   SW1/4    SW1/5   SW1/6    SW1/7   SW1/8

   0       -       -        -       -       -        -       -        -

   1      Off      On      On      On       On      On       On      On

   2      On      Off      On      On       On      On       On      On

   3      Off     Off      On      On       On      On       On      On

   4      On       On      Off     On       On      On       On      On

  251     Off     Off      On      Off     Off      Off     Off      Off

  252     On       On      Off     Off     Off      Off     Off      Off

  253     Off      On      Off     Off     Off      Off     Off      Off

  254     On      Off      Off     Off     Off      Off     Off      Off

  255     Off     Off      Off     Off     Off      Off     Off      Off

            Notes:Node address 0 is used for messaging between nodes and
            must not be used. A total of 255 node address settings are
            available. The switches are a binary representation of the
            decimal node addresses. Switch 1 is the Least Significant Bit
            and switch 8 is the Most Significant Bit. The switches have
            the following decimal values: switch 1=1, 2=2, 3=4, 4=8,
            5=16, 6=32, 7=64, 8=128. Turn off the switches and add the
            values of the off switches to obtain the correct node
            address. (On=0, Off=1)

                           CABLE TYPE & TOPOLOGY

    Type        Topology       JP7         JP8        JP10        JP12

   Coaxial        Star       Closed       Open        Open        Open

   Coaxial     Linear Bus     Open       Closed       Open        Open

   Twisted        Star        Open        Open       Closed      Closed
    pair

   Twisted     Linear Bus     Open        Open       Closed      Closed
    pair

                            BASE MEMORY ADDRESS

   Address        JP5A &      SW2/7      SW2/8       SW2/9       SW2/10
                  JP5B

    C0000h       Closed        Off        Off         On           On

    CC000h        Open         Off        Off         On           On

    D0000h       Closed        Off        Off         On          Off

    DC000h        Open         Off        Off         On          Off

    E0000h       Closed        Off        Off         Off          On

                                           INTERRUPT SETTINGS

  IRQ   JP6A     JP6B     JP6C     JP6D     JP6E    JP6F     JP6G     JP6H     JP6I     JP6J     JP6K

  2     Open     Open     Open     Open     Open    Closed   Open     Open     Open     Open     Open

  3     Closed   Open     Open     Open     Open    Open     Open     Open     Open     Open     Open

  4     Open    Closed    Open     Open     Open    Open     Open     Open     Open     Open     Open

  5     Open     Open    Closed    Open     Open    Open     Open     Open     Open     Open     Open

  6     Open     Open     Open    Closed    Open    Open     Open     Open     Open     Open     Open

  7     Open     Open     Open     Open    Closed   Open     Open     Open     Open     Open     Open

  10    Open     Open     Open     Open     Open    Open     Closed   Open     Open     Open     Open

  11    Open     Open     Open     Open     Open    Open     Open     Closed   Open     Open     Open

  12    Open     Open     Open     Open     Open    Open     Open     Open     Closed   Open     Open

  14    Open     Open     Open     Open     Open    Open     Open     Open     Open    Closed    Open

  15    Open     Open     Open     Open     Open    Open     Open     Open     Open     Open    Closed

                   RESPONSE AND RECONFIGURATION TIMEOUTS

  Response Time   Idle Time     Reconfiguration        JP9        JP11
                                     Time

       78s        86s             840ms            Open        Open

        285s       316s           1680ms            Open       Closed

        563s       624s           1680ms           Closed       Open

       1130s      1237s           1680ms           Closed      Closed

  Note:All NICs on the network segment must have this option set the
  same.

                             I/O BASE ADDRESS

   Address      SW2/1     SW2/2     SW2/3     SW2/4     SW2/5     SW2/6

      2E0h      Off       On        Off       Off       Off        On

       2F0h      Off       On        Off       Off       Off       Off

       300h      Off       Off       On        On        On         On

       350h      Off       Off       On        Off       On        Off

                             DIAGNOSTIC LED(S)

     LED         Color         Status                 Condition

    LED1         Green        Blinking       Data is being transmitted or
                                                      received

    LED1         Green           Off        Data is not being transmitted
                                                     or received

                            MISCELLANEOUS NOTES

  The AL-3353 and the AL-3354 have different transceivers. As a result
  the AL-3353 should only be operated in a coaxial star configuration,
  while the AL-3354 will operate in a coaxial bus, a coaxial star, a
  twisted pair bus or a twisted pair star configuration.