DANPEX CORPORATION

EN-9000

NIC Type      Ethernet
Transfer Rate 10Mbps
Data Bus      32-bit EISA
Topology      Star

              Linear Bus
Wiring Type   RG58A/U 50ohm coaxial

              Shielded/Unshielded twisted pair

              AUI transceiver via DB-15 port
Boot ROM      Available

[Image]

                            ACTIVITY LED ENABLE

                Setting                                 JP1

                 Disabled                       Pins 1 & 2 closed

                   Enabled                       Pins 2 & 3 closed

  Note:If the network hub has an activity LED for each line, setting this
  option to enabled will allow the hub LED to operate properly

                                CABLE TYPE

                  Type                                  JP6

              Software select                   Pins 1 & 2 closed

            RG58A/U 50ohm coaxial                Pins 2 & 3 closed

                            ONBOARD TERMINATOR

                Setting                                 JP7

                 Disabled                       Pins 2 & 3 closed

                   Enabled                       Pins 1 & 2 closed

       Note:When using RG58A/U 50ohm coaxial cable the onboard 50ohm
       terminator may be used instead of using a T-connector and an
       external terminator.

                             DIAGNOSTIC LED(S)

         LED                  Status                   Condition

        LED1                    On             Data is being transmitted

        LED1                   Off                 Data is not being
                                                      transmitted

        LED2                    On             Twisted pair connection is
                                                         good

        LED2                   Off             Twisted pair connection is
                                                        broken

        LED3                    On              Data is being received

        LED3                   Off            Data is not being received

        LED4                    On               Collision detected on
                                                        network

        LED4                   Off             No collisions detected on
                                                        network

  FACTORY CONFIGURED SETTINGS

     Jumper         Setting

      JP2            Unused

      JP3            Unused

      JP4            Unused

      JP5            Unused