DANPEX CORPORATION

AN-500S /AN-500B

NIC Type      ARCnet
Transfer Rate 2Mbps
Data Bus      8-bit ISA
Topology      Star (AN-500S)

              Linear Bus (AN-500B)
Wiring Type   Shielded/Unshielded twisted pair

              RG62A/U 93ohm coaxial
Boot ROM      Available

[Image]

                               NODE ADDRESS

  Node   SW2/1    SW2/2   SW2/3   SW2/4    SW2/5   SW2/6    SW2/7   SW2/8

   0       -       -        -       -       -        -       -        -

   1      On       On      On      On       On      On       On      Off

   2      On       On      On      On       On      On      Off      On

   3      On       On      On      On       On      On      Off      Off

  252     Off     Off      Off     Off     Off      Off      On      On

  253     Off     Off      Off     Off     Off      Off      On      Off

  254     Off     Off      Off     Off     Off      Off     Off      On

  255     Off     Off      Off     Off     Off      Off     Off      Off

  Note: Node address 0 is used for messaging between nodes and must not
  be used.

       A total of 255 node address settings are available. The switches
       are a binary representation of the decimal node addresses. Switch
       8 is the Least Significant Bit and switch 1 is the Most
       Significant Bit. The switches have the following decimal values:
       switch 8=1, 7=2, 6=4, 5=8, 4=16, 3=32, 2=64, 1=128. Turn off the
       switches and add the values of the off switches to obtain the
       correct node address. (On=0, Off=1)

                   RESPONSE AND RECONFIGURATION TIMEOUTS

    Response    Idle Time     Reconfiguration        JP1          JP2
     Time                          Time

     78s         86s             840ms             Open         Open

     285s        316s           1680ms            Closed        Open

     563s        624s           1680ms             Open        Closed

    1130s       1237s           1680ms            Closed       Closed

  Note: All NICs on the network must have this option set the same.

                                           INTERRUPT REQUEST

  IRQ    JP3     JP4      JP5      JP6      JP7      JP8      JP9     JP10     JP11     JP12     JP13

  2     Open     Open     Open     Open     Open    Open     Open     Open     Open     Open    Closed

  3     Open     Open     Open     Open     Open    Closed   Open     Open     Open     Open     Open

  4     Open     Open     Open     Open     Open    Open     Closed   Open     Open     Open     Open

  5     Open     Open     Open     Open     Open    Open     Open     Closed   Open     Open     Open

  6     Open     Open     Open     Open     Open    Open     Open     Open     Closed   Open     Open

  7     Open     Open     Open     Open     Open    Open     Open     Open     Open    Closed    Open

  10    Open     Open     Open     Open    Closed   Open     Open     Open     Open     Open     Open

  11    Open     Open     Open    Closed    Open    Open     Open     Open     Open     Open     Open

  12    Open     Open    Closed    Open     Open    Open     Open     Open     Open     Open     Open

  14    Closed   Open     Open     Open     Open    Open     Open     Open     Open     Open     Open

  15    Open    Closed    Open     Open     Open    Open     Open     Open     Open     Open     Open

                            ONBOARD TERMINATOR

                 Setting                               JP14

                  Disabled                            Open

                   Enabled                            Closed

  Note:If the card is the last in the line of network cards, the onboard
  terminator may be enabled instead of using a T-connector and an
  external terminator. This setting is valid only with the AN-500B. If
  using model AN-500S, JP14 must be open. (Star topologies do not require
  the use of terminators)

      CARD TYPE

   Card       JP15

  AN-500S     Open

  AN500B     Closed

                             I/O BASE ADDRESS

   Address      SW1/1     SW1/2     SW1/3     SW1/4     SW1/5     SW1/6

      2E0h      Off       On        Off       Off       Off        On

       2F0h      Off       On        Off       Off       On        Off

       300h      Off       Off       On        On        On         On

                            RIM BUFFER ADDRESS

      Address           SW1/7        SW1/8        SW1/9         SW1/10

         C0000 -         Off          Off           On            On
         C07FFh

        D0000 -         Off          Off           On           Off
         D07FFh

         E0000 -         Off          Off          Off            On
         E07FFh

                             DIAGNOSTIC LED(S)

       LED               Status                     Condition

       LED1                On             Card is receiving power and is
                                                operating properly

       LED1             Flashing           Data is being transmitted or
                                                     received

       LED1                Off            Card is not receiving power or
                                                   is defective