PURE DATA, LTD.

PDI8023-16T

NIC Type      Ethernet
Transfer Rate 10Mbps
Data Bus      16-bit ISA
Topology      Star
Wiring Type   Unshielded twisted pair
Boot ROM      Available

[Image]

                       SOFTWARE CONFIGURATION RESET

                 Setting                                 E1

              Normal operation                  Pins 2 & 3 closed

                     Reset                       Pins 1 & 2 closed

  Note:Many of the options are configured using the setup utility
  provided with the card. To reset those configurations to the factory
  defaults, move E1 to the Reset position (pins 1 & 2 closed) and apply
  power for a few seconds. Always make sure that you turn off the power
  to the computer before you change any jumpers.

                              CARD I/D NUMBER

    Number           E2A            E2B            E2C           E2D

        1           Open          Open           Open          Closed

         2           Open          Open          Closed          Open

         3           Open         Closed          Open           Open

         4          Closed         Open           Open           Open

       Note:Up to four cards can be installed into a system at the same
       time. If more than one card is installed each one must have a
       seperate card I/D number.

                            LINK INTEGRITY TEST

                Setting                                 E3

                  Enabled                       Pins 1 & 2 closed

                  Disabled                       Pins 2 & 3 closed

  FACTORY CONFIGURED SETTINGS

     Jumper         Setting

      E5A             Open

      E5B             Open

      E5C            Closed

                             DIAGNOSTIC LED(S)

     LED         Color         Status                Condition

    LED1          Red            On        Card is being accessed by host
                                                      computer

    LED1          Red           Off         Card is not being accessed by
                                                   host computer

    LED2         Green           On         Data is being transmitted or
                                                      received

    LED2         Green          Off         Data is not being transmitted
                                                    or received

    LED3          Red            On        Receive wires are reversed and
                                                   corrected for

    LED3          Red           Off               Normal operation

    LED4         Green           On          Network connection is good

    LED4         Green          Off         Network connection is broken

  Note:If LED3 is lit the receive wires are reversed. The card will
  automatically correct for this but the wires should be repaired as soon