PURE DATA, LTD.

PDI8023-16FL

NIC Type          Ethernet
Transfer Rate     10Mbps
Data Bus          16-bit ISA
Topology          Star
Wiring Type       62.5/125 m m Fiber optic cable (e.g. Belden
                  227412)
Boot ROM          Available

[Image]

                       SOFTWARE CONFIGURATION RESET

                 Setting                                 E1

              Normal operation                  Pins 2 & 3 closed

                     Reset                       Pins 1 & 2 closed

  Note:Many of the options are configured using the setup utility
  provided with the card. To reset those configurations to the factory
  defaults, move E1 to the Reset position (pins 1 & 2 closed) and apply
  power for a few seconds. Always make sure that you turn off the power
  to the computer before you change any jumpers.

                              CARD I/D NUMBER

     Number          E2A            E2B            E2C            E2D

         1          Open           Open          Open          Closed

          2          Open           Open         Closed          Open

          3          Open          Closed         Open           Open

          4         Closed          Open          Open           Open

       Note:Up to four cards can be installed into a system at the same
       time. If more than one card is installed each one must have a
       seperate card I/D number.

       EXTENDED TRANSMIT TIMEOUT AND SIGNAL QUALITY ERROR (SQE) TEST

    Timeout           SQE            E6A           E6B            E6C

    Enabled         Enabled         Closed         Open          Open

    Disabled        Disabled         Open         Closed         Open

    Enabled         Disabled         Open          Open         Closed

  Note:With extended transmit timeout enabled, if the card is
  transmitting for an extented amount of time the transmission will be
  interrupted and continued after a preset time. This keeps the card from
  dominating the network.

  Signal Quality Error (SQE) is a test of the collision circuitry and
  path.

  E6 is located on the PIM.

                             LOOP BACK ENABLE

                 Setting                                E7

                  Disabled                      Pins 1 & 2 closed

                   Enabled                       Pins 2 & 3 closed

  Note:A loop back connector is used with diagnostic software to
  trouble-shoot the card.

  E7 is located on the PIM.

  FACTORY CONFIGURED SETTINGS

     Jumper         Setting

      E5A            Closed

      E5B             Open

      E5C             Open

                             DIAGNOSTIC LED(S)

     LED         Color        Status                 Condition

    LED1         Green          On           Data is being transmitted

    LED1         Green          Off        Data is not being transmitted

    LED2         Amber          On            Data is being received

    LED2         Amber          Off         Data is not being received

    LED3         Amber          On          Network connection is good

    LED3         Amber          Off        Network connection is broken

    LED4          Red           On          Card is transmitting for an
                                                   extended time

    LED4          Red           Off              Normal operation

    LED5          Red           On         Collision detected on network

    LED5          Red           Off              Normal operation