COMPEX, INC.

ENET16/P

NIC Type      Ethernet
Transfer Rate 10Mbps
Data Bus      16-bit ISA
Topology      Linear bus
Wiring Type   RG-58A/U 50ohm coaxial

              AUI transceiver via DB-15 port
Boot ROM      Available

[Image]

                              SEGMENT LENGTH

             Maximum Length                             J1

                185 meters                           Closed

                 300 meters                            Open

       Note:Segment length is the total length of cable between the two
       farthest cards on the segment. Each card on the segment must have
       this option set the same.

                              NETWORK VERSION

                 Version                                J2

            Ethernet version 2                        Open

             Ethernet version 1                       Closed

      INTERRUPT REQUEST

   IRQ       J4A      J4B

    4       Closed    Open

    5       Closed   Closed

    7       Open     Closed

                   I/O BASE ADDRESS

  Address     J5A        J5B        J5C        J5D

   200h      Closed     Closed    Closed     Closed

   240h      Closed     Closed     Open      Closed

   280h      Closed      Open     Closed     Closed

   2C0h      Closed      Open      Open      Closed

   300h       Open      Closed    Closed     Closed

   340h       Open      Closed     Open      Closed

   380h       Open       Open     Closed     Closed

   3C0h       Open       Open      Open      Closed

                             DIAGNOSTIC LED(S)

       LED              Status                     Condition

       LJ1                On              Data is being transmitted or
                                                    received

       LJ1                Off           Data is not being transmitted or
                                                    received