ADDTRON TECHNOLOGY COMPANY, LTD.

AE-200LC

NIC Type      Ethernet
Transfer Rate 10Mbps
Data Bus      16-bit ISA
Topology      Linear Bus
Wiring Type   Unshielded twisted pair

              RG-58A/U 50ohm coaxial
Boot ROM      Available

[Image]

                             I/O BASE ADDRESS

          Address                    JP1A                    JP1B

             300h                   Open                    Open

              320h                  Closed                   Open

              340h                   Open                   Closed

              360h                  Closed                  Closed

                             INTERRUPT REQUEST

  IRQ     JP2A     JP2B      JP2C      JP2D     JP2E      JP2F     JP2G

   2     Closed    Open      Open      Open     Open      Open     Open

   3      Open     Closed    Open      Open     Open      Open     Open

   4      Open     Open     Closed     Open     Open      Open     Open

   5      Open     Open      Open     Closed    Open      Open     Open

  10      Open     Open      Open      Open     Closed    Open     Open

  11      Open     Open      Open      Open     Open     Closed    Open

  12      Open     Open      Open      Open     Open      Open     Closed

                             BOOT ROM ADDRESS

      Address            JP3A         JP3B          JP3C          JP3D

       Disabled         Open         Open          Open          Open

         C8000h         Closed        Open         Closed         Open

         CC000h         Closed       Closed        Closed         Open

         D0000h         Closed        Open          Open         Closed

         D4000h         Closed       Closed         Open         Closed

         D8000h         Closed        Open         Closed        Closed

         DC000h         Closed       Closed        Closed        Closed

                            COMPATIBILITY MODE

                 Setting                                JP4

                  Enabled                       Pins 1 & 2 closed

                   Disabled                      Pins 2 & 3 closed

       Note: On some systems the data bus timing is not truly IBM PC/AT
       compatible. If the card does not initialize or you receive an
       "Error Reading Address PROM" message, compatibility mode should be
       enabled.

                                CABLE TYPE

                   Type                                 JP5

           RG-58A/U 50ohm coaxial               Pins 2 & 3 closed

            Unshielded twisted pair              Pins 1 & 2 closed

[Image]

                             DIAGNOSTIC LED(S)

    LED        Color       Status                  Condition

   LED1         Red          Off                data is not being
                                              transmitted/received

   LED1         Red          On        data is being transmitted/received

   LED2        Green         On          10BaseT link integrity exists

   LED2        Green         Off         10BaseT link integrity broken

  Note: LED2 is only functional when link integrity is enabled, and when
  installed on a 10BaseT network.