
MADGE NETWORKS, LTD.

SMART 16/4 CLIENT RINGNODE

NIC Type      Token Ring
Transfer Rate 4/16Mbps
Data Bus      16-bit ISA
Topology      Ring
Wiring Type   Shielded/Unshielded twisted pair
Boot ROM      Available

[Image]

                                 BOOT ROM

                 Setting                               SW2/3

                  Disabled                             Off

                   Enabled                               On

                            COMPATIBILITY MODE

                 Setting                               SW2/6

            Normal ISA bus timing                       On

           Alternate ISA bus timing                     Off

       Note:Alternate ISA bus timing is used if the host computer is not
       100% ISA bus compatible (such as the IBM PS/2 model 30-286) or if
       the Madge Ringnode diagnostics program fails to locate the NIC.

                              DMA CHANNEL BUS

                  Setting                               SW2/7

          Asynchronous bus (uses host                   Off
                systems clock)

       Synchronous bus (uses NIC on-board                 On
                     clock)

  Note:The synchronous bus speed is used for systems that have a clock
  speed less than 10MHz.

                            EXPANSION SLOT SIZE

                Slot Size                              SW2/5

              Automatic select                          On

               Forced 8-bit mode                        Off

       Note:If an 8-bit transfer mode is required and the NIC is
       installed in a 16-bit slot, use forced 8-bit mode. If the NIC is
       to be used in a Novell Netware 386 file server, automatic select
       must be used.

                             INTERRUPT REQUEST

                 IRQ                                  SW1

                   3                              Position 7

                   2/9                             Position 8

                    5                              Position 6

                    7                              Position 5

                    10                             Position 4

                    11                             Position 3

                    12                             Position 2

                    15                             Position 1

                               NETWORK SPEED

                 Speed                                 SW2/7

                  16Mbps                               Off

                    4Mbps                               On

  Note:All cards on a segment must have this option set the same.

                       BASE I/O AND BOOT ROM ADDRESS

        Address           Boot ROM Address        SW2/1         SW2/2

        0A20-0A2Fh         CC000-CDFFFh           On             On

         1A20-1A2Fh         DC000-DDFFFh           Off            On

         2A20-2A2Fh         CE000-CFFFFh           On            Off

         3A20-3A2Fh         DE000-DFFFFh           Off           Off

                                CABLE TYPE

                  Type                                  LB1

  Shielded twisted pair (DB-9 connector)                STP

  Unshielded twisted pair (RJ-45 jack)                  UTP

