DANPEX CORPORATION

AN-500T/AN-202T/AN-808T/AN-202L

NIC Type      ARCnet
Transfer Rate 2.5Mbps
Data Bus      16-bit ISA
Topology      Linear Bus

              Star
Wiring Type   Unshielded twisted pair
Boot ROM      Available

[Image]

                        BASE MEMORY ADDRESS SELECT

         Address            SW1/7       SW1/8       SW1/9       SW1/10

      D0000h - D07FFh       Off         Off          On          Off

       C0000h - C07FFh       Off         Off          On          On

       E0000h - E07FFh       Off         Off         Off          On

                             INTERRUPT SELECT

     IRQ         JP8       JP9       JP10      JP11      JP12      JP13

     IRQ9/2     Open      Open      Open      Open      Open     Closed

       IRQ3     Closed     Open      Open      Open      Open      Open

       IRQ4      Open     Closed     Open      Open      Open      Open

       IRQ5      Open      Open     Closed     Open      Open      Open

       IRQ6      Open      Open      Open     Closed     Open      Open

       IRQ7      Open      Open      Open      Open     Closed     Open

                  INTERRUPT SELECT (CONTINUED)

    IRQ        JP3        JP4        JP5        JP6       JP7

   IRQ14     Closed      Open       Open       Open       Open

   IRQ15      Open      Closed      Open       Open       Open

   IRQ12      Open       Open      Closed      Open       Open

   IRQ11      Open       Open       Open      Closed      Open

   IRQ10      Open       Open       Open       Open      Closed

                            I/O ADDRESS SELECT

   Address      SW1/1     SW1/2     SW1/3     SW1/4     SW1/5      SW1/6

      2E0h      Off       On        Off       Off       Off        On

       2F0h      Off       On        Off       Off       Off        Off

       300h      Off       Off       On         On        On        On

                               NODE ADDRESS

  Node   SW2/1    SW2/2   SW2/3   SW2/4    SW2/5   SW2/6    SW2/7   SW2/8

   0       -       -        -       -       -        -       -        -

   1      On       On      On      On       On      On       On      Off

   2      On       On      On      On       On      On      Off      On

   3      On       On      On      On       On      On      Off      Off

   4      On       On      On      On       On      Off      On      On

  251     Off     Off      Off     Off     Off      On      Off      Off

  252     Off     Off      Off     Off     Off      Off      On      On

  253     Off     Off      Off     Off     Off      Off      On      Off

  254     Off     Off      Off     Off     Off      Off     Off      On

  255     Off     Off      Off     Off     Off      Off     Off      Off

  Note:Node address 0 is used for messaging between nodes and must not be
  used.

       A total of 255 node address settings are available. The switches
       are a binary representation of the decimal node addresses. Switch
       8 is the Least Significant Bit and switch 1 is the Most
       Significant Bit. The switches have the following decimal values:
       switch 1=128, 2=64, 3=32, 4=16, 5=8, 6=4, 7=2, 8=1. Turn Off the
       switches and add the values of the Off switches to obtain the
       correct node address. (On=0, Off=1)

                   RESPONSE AND RECONFIGURATION TIMEOUTS

  Reconfiguration Time   IDL Time (  Response Time      JP1        JP2
                             m            ( m

           840ms           86            78           Open       Open

          1.68 sec          316           285         Closed      Open

          1.68 sec          624           563          Open      Closed

          1.68 sec         1237          1130         Closed     Closed

                             TERMINATOR SELECT

               Setting                                JP14

   Card used at end of Linear Bus                    Closed

  Card not used at end of Linear Bus                  Open

                              DIAGNOSTIC LED

      Color             Status                     Condition

      Green               On                       PC is on

      Green            Blinking       Data is being transmitted/received

  FACTORY CONFIGURED SETTINGS

     Jumper         Setting

      JP15           Closed