SYSKONNECT, INC.

FDDI-FI/FDDI-TI/FDDI-SI

NIC Type      FDDI
Transfer Rate 100Mbps
Data Bus      16-bit ISA
Topology      FDDI ring
Wiring Type   IBM Type 1
Boot ROM      Available (location unidentified)

[Image]

                                 BOOT ROM

       Setting            W2/5         W2/6         W2/7         W2/8

        Disabled          Off          Off          Off          Off

       Note:Options for enabling the BOOT ROM are available in the form
       of a software package provided by the manufacturer.

                          DMA CONFIGURATION

  DMA    W3/1    W3/2    W3/3    W3/4   W3/5    W3/6    W3/7    W3/8

   3      Off     Off    Off     Off     Off     Off     On      On

   5      Off     Off    Off     Off     On      On     Off     Off

   6      Off     Off     On      On     Off     Off    Off     Off

   7      On      On     Off     Off     Off     Off    Off     Off

            I/O ADDRESS SELECT

  Address     W2/1       W2/2      W2/3

   100h       Off        Off        Off

   120h       Off        Off        On

   180h       Off         On        Off

   1A0h       Off         On        On

   220h        On        Off        Off

   240h        On        Off        On

   320h        On         On        Off

   340h        On         On        On

                           INTERRUPT SELECT

  IRQ    W4/1    W4/2    W4/3    W4/4   W4/5    W4/6    W4/7    W4/8

  2/9     Off     Off    Off     Off     Off     Off    Off      On

   3      Off     Off    Off     Off     On      Off    Off     Off

   4      Off     Off    Off     Off     Off     On     Off     Off

   5      Off     Off    Off     Off     Off     Off     On     Off

   10     Off     Off    Off      On     Off     Off    Off     Off

   11     Off     Off     On     Off     Off     Off    Off     Off

   12     Off     On     Off     Off     Off     Off    Off     Off

   15     On      Off    Off     Off     Off     Off    Off     Off

                                SYSTEM TYPE

                   Type                                  W1

             Non-IBM compatible                       Closed

                IBM compatible                          Open

  FACTORY CONFIGURED SETTINGS

     Switch         Setting

      W2/4            N/A