COMPU-SHACK PRODUCTION, GMBH

CS-ARCNET-KARTE (REV. 3.31/3.31S)

NIC Type:      ARCnet
Transfer Rate: 2.5Mbps
Data Bus:      8-bit ISA
Topology:      Linear Bus
Wiring Type    RG62A/U 93ohm coaxial
Boot ROM       Available

[Image]

                           INTERRUPT SELECT - J2

     IRQ        Jumper A    Jumper B    Jumper D    Jumper D    Jumper E

      IRQ2      Closed       Open        Open        Open        Open

       IRQ3       Open       Closed       Open        Open        Open

       IRQ4       Open        Open       Closed       Open        Open

       IRQ5       Open        Open        Open       Closed       Open

       IRQ7       Open        Open        Open        Open       Closed

                            RESPONSE TIME-OUTS

       Response Time             J4/jumper A             J4/jumper B

            74.7s                  Open                   Open

            283.4s                 Closed                  Open

            561.8s                  Open                  Closed

            1118.6s                Closed                 Closed

                                I/O ADDRESS

  Address     S1/1       S1/2      S1/3       S1/4      S1/5       S1/6

   2E0h       Off         On        Off       Off        Off        On

   200h       Off         On        On         On        On         On

   210h       Off         On        On         On        On        Off

   220h       Off         On        On         On        Off        On

                                I/O ADDRESS

  Address     S1/1       S1/2      S1/3       S1/4      S1/5       S1/6

   230h       Off         On        On         On        Off       Off

   240h       Off         On        On        Off        On         On

   250h       Off         On        On        Off        On        Off

   260h       Off         On        On        Off        Off        On

   270h       Off         On        On        Off        Off       Off

   280h       Off         On        Off        On        On         On

   290h       Off         On        Off        On        On        Off

   2A0h       Off         On        Off        On        Off        On

   2B0h       Off         On        Off        On        Off       Off

   2C0h       Off         On        Off       Off        On         On

   2D0h       Off         On        Off       Off        On        Off

   2F0h       Off         On        Off       Off        Off       Off

   300h       Off        Off        On         On        On         On

   310h       Off        Off        On         On        On        Off

   320h       Off        Off        On         On        Off        On

   330h       Off        Off        On         On        Off       Off

   340h       Off        Off        On        Off        On         On

   350h       Off        Off        On        Off        On        Off

   360h       Off        Off        On        Off        Off        On

   370h       Off        Off        On        Off        Off       Off

   380h       Off        Off        Off        On        On         On

   390h       Off        Off        Off        On        On        Off

   3A0h       Off        Off        Off        On        Off        On

   3B0h       Off        Off        Off        On        Off       Off

   3C0h       Off        Off        Off       Off        On         On

   3D0h       Off        Off        Off       Off        On        Off

   3E0h       Off        Off        Off       Off        Off        On

   3F0h       Off        Off        Off       Off        Off       Off

                    MEMORY ADDRESS

  Address     S1/7       S1/8      S1/9       S1/10

  C0000h      Off        Off        On         On

  D0000h      Off        Off        On         Off

  E0000h      Off        Off        Off        On

                              NODE ID NUMBER

  ID #   S2/1    S2/2     S2/3    S2/4    S2/5    S2/6     S2/7     S2/8

   1      On      Off     Off     Off      Off     Off     Off      Off

  255     On      On       On      On      On      On       On       On

  Note:Nodes can be numbered from 1 to 255. The switches are a binary
  representation of the node numbers. When a switch is on, the
  corresponding bit is set to 1 and has the following decimal value:
  S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128.

                              DIAGNOSTIC LED

            Status                             Condition

              On                 Data is being transmitted or received

             Off                Data is not being transmitted or received