CORVUS SYSTEMS, INC.

TRANSPORTER MODEL 8010-10440

NIC Type              OmniNet (proprietary)
Network Transfer Rate Unidentified
Data Bus              8-bit ISA
Topology              Linear Bus
Wire Type             Shielded/Unshielded twisted pair
Boot ROM              Available

[Image]

                                CONNECTIONS

               Function                               Label

  Unshielded or shielded twisted pair                  CN1
  via 1/8" plug

                        USER CONFIGURABLE SETTINGS

                   Setting                      Label        Position

     Factory configured - do not alter          E2          Pins 1 & 2
                                                              closed

                               NODE ADDRESS

  Setting      U14/1     U14/2     U14/3     U14/4      U14/5     U14/6

     0          On        On         On        On        On         On

     1          Off       On         On        On        On         On

     2          On        Off        On        On        On         On

     3          Off       Off        On        On        On         On

     4          On        On        Off        On        On         On

     59         Off       Off        On       Off        Off       Off

     60         On        On        Off       Off        Off       Off

     61         Off       On        Off       Off        Off       Off

     62         On        Off       Off       Off        Off       Off

     63         Off       Off       Off       Off        Off       Off

            Note: A total of 64 node address settings are available. The
            switches are a binary representation of the decimal node
            addresses. U14/6 is the Most Significant Bit and switch U14/1
            is the Least Significant Bit. The switches have the following
            decimal values: U14/6=32, U14/5=16, U14/4=8, U14/3=4,
            U14/2=2, U14/1=1. Turn off the switches and add the values of
            the switches that are off to obtain the correct node ID.
            (Off=1, On=0)

                             BIAS SELECTION

        Setting                  U14/7                    U14/8

         Normal                   Off                      Off

         Biased                    On                      On

            Note:Only one machine per network should be set to biased.

                             BASE I/O ADDRESS

     Setting          E1/A          E1/B          E1/C           E1/D

         240h        Closed         Open          Open           Open

        248h         Open         Closed         Open           Open

         250h         Open          Open         Closed          Open

         258h         Open          Open          Open          Closed

            Note:E1 is a set of solder contacts. To change the address,
            you must cut the trace on E1/C andhard-wire a jumper with a
            soldering gun.