Compatible systems corporation

Ether+ utp

Card Type             Network Interface Card
NIC Type              Ethernet
Network Transfer Rate 10Mbps
Topology              Linear Bus, Star
Wiring Type           Unshielded twisted pair

                      AUI transceiver via DB-15
Data Bus              SCSI
Boot ROM              Not available

[Image]

                                CONNECTIONS

         Function            Label           Function            Label

  Unshielded twisted          CN1       25-pin SCSI               CN3
  pair                                  connector - external

  AUI transceiver via         CN2
  DB-15

  Note: 50-pin to 25-pin adapter cables are available.

   USER CONFIGURABLE SETTINGS

  SCSI ID      SW/1 Position

     0               0

     1               1

     2               2

     3               3

     4               4

     5               5

     6               6

  Invalid           7-9

           CABLE TYPE SELECTION

            Type                  JP1

  AUI transceiver via DB-15       Open

  Unshielded twisted pair        Closed

                             DIAGNOSTIC LED(S)

   LED       Color         Status                  Condition

    1        Green           On         Receive data line polarity error

    1        Green          Off           No receive data line polarity
                                                     error

    2        Green        Blinking           Data is being received

    2        Green          Off            Data is not being received

    3        Green        Blinking           Data is being received

    3        Green          Off            Data is not being received

    4        Green        Blinking           Data is being received

    4        Green          Off            Data is not being received

    5        Green        Blinking           Data is being received

    5        Green          Off            Data is not being received

    6        Green        Blinking         Data is being transmitted

    6        Green          Off          Data is not being transmitted

    7        Green        Blinking         Data is being transmitted

    7        Green          Off          Data is not being transmitted

    8        Green        Blinking         Data is being transmitted

    8        Green          Off          Data is not being transmitted

    9        Green        Blinking         Data is being transmitted

    9        Green          Off          Data is not being transmitted

    10       Green           On           10BaseT link test successful

    10       Green          Off          10BaseT link test unsuccessful

                                   Note:

  When data is being received, LEDs 2 through 5 will light in sequence.
  When data is being transmitted, LEDs 9 through 6 will light in
  sequence.