COMPU-SHACK PRODUCTION, GMBH

CS-FDDI PCI-MMF-SAS

Card Type              Network Interface Card
NIC Type               FDDI
Maximum Onboard Memory Unidentified
Boot ROM               Available
Network Transfer Rate  100Mbps
Topology               Ring
Wiring Type            Fiber optic cable
Data Bus               32-bit PCI

[Image]

                           CONNECTIONS

            Function                          Label

  Fiber-optic connector via MIC                CN1

                        USER CONFIGURABLE SETTINGS

               Function                   Label            Position

     Boot ROM disabled                   JP13/A             Open

      Boot ROM enabled                    JP13/A            Closed

     Factory configured - do not         JP13/E         Unidentified
      alter

     Factory configured - do not          JP3           Unidentified
      alter

                        BASE I/O ADDRESS SELECTION

        Address              JP13/B           JP13/C           JP13/D

          200h-21Fh          Closed           Closed           Closed

          220h-23Fh          Closed           Closed            Open

          240h-25Fh          Closed            Open            Closed

          280h-29Fh          Closed            Open             Open

         300h-31Fh           Open            Closed           Closed

          320h-33Fh           Open            Closed            Open

          340h-35Fh           Open             Open            Closed

                             DIAGNOSTIC LED(S)

   LED         Color         Status                 Condition

  LED1      Unidentified       On         See conditions in note below

  LED1      Unidentified       Off        See conditions in note below

  LED2          Red            On       Cable fault detected (SDDI only)

  LED2          Red            Off        No cable fault detected (SDDI
                                                      only)

  LED3         Green           On          Network connection is good

  LED3         Green           Off        Network connection is broken

  LED4         Yellow          On                 Data is being
                                              transmitted/received

  LED4         Yellow          Off              Data is not being
                                              transmitted/received

  Note: LED1 varies depending on model. Green (On: UTP link is good, Off:
  UTP link is broken); Red (On: Illegal connection, Off: Valid
  connection); or Orange (On: Line error alarm activated, Off: Line error
  alarm not activated).

[Image]

        USER CONFIGURABLE SETTINGS

  Note: JP14 and JP16 are unidentified.