GARRETT COMMUNICATIONS

MAGNUM 110

Card Type                 Ethernet Transceiver
NIC Type                  Ethernet
Maximum Onboard Memory    Unidentified
Boot ROM                  Not available
Network Transfer Rate     10Mbps
Topology                  Linear Bus
Wiring Type               AUI transceiver via DB-15 port, RG-58A/U 50ohm
                          coaxial
Data Bus                  External

[Image]

                                CONNECTIONS

        Function            Label            Function            Label

  BNC-T network tap          CN1       AUI connector              CN2
  connector

                        USER CONFIGURABLE SETTINGS

                  Function                      Label        Position

      SQE on with LED indication                  J1         Pins 1 & 2
                                                              closed

      SQE on without LED indication               J1           Open

     SQE off                                     J1         Pins 2 & 3
                                                              closed

                          DIAGNOSTIC LED(S)

  LED     Color    Status                  Condition

  LED1   Yellow      On          Collision detected on network

  LED1   Yellow      Off       Collision not detected on network

  LED2    Amber      On               Jabber has occurred

  LED2    Amber      Off            Jabber has not occurred

  LED3    Green      On                   Power is on

  LED3    Green      Off                  Power is off

  LED4    Green      On            Data is being transmitted

  LED4    Green      Off         Data is not being transmitted

  LED5   Yellow      On                   SQE enabled

  LED5   Yellow      Off                  SQE disabled

  LED6    Green      On              Data is being received

  LED6    Green      Off           Data is not being received