PLASMON DATA, INC.

RF7030I

Device Type            Internal CD-ROM
Interface              SCSI
Spin Rate (Read)       2x
Formats Supported Read Unidentified
View                   Top


                        USER CONFIGURABLE SETTINGS

             Setting                   Label              Position

      Automatic spin on power up       JP1/1               Closed
      enabled

      Automatic spin on power up       JP1/1                Open
      disabled

     Factory configured - do          JP1/2              Reserved
      not alter

      Termination power enabled        JP1/3               Closed

      Termination power disabled       JP1/3                Open

      Terminator enabled               JP1/4               Closed

      Terminator disabled              JP1/4                Open

     Factory configured - do          JP1/5              Reserved
      not alter

     Parity check enabled             JP1/8               Closed

      Parity check disabled            JP1/8                Open

     Factory configured - do          JP1/10             Reserved
      not alter

     Factory configured - do           JP2             Unidentified
      not alter

     Built in terminator              SW1/4                 On
      enabled

      Built in terminator              SW1/4                 Off
      disabled

     Drive to supply terminator       SW1/5                 On
      power enabled

      Drive to supply terminator       SW1/5                 Off
      power disabled

     Parity check enabled             SW1/6                 On

      Parity check disabled            SW1/6                 Off

     Automatic media spin-up          SW1/7                 On
      enabled

      Automatic media spin-up          SW1/7                 Off
      disabled

     Factory configured - do          SW1/8              Reserved
      not alter

                         EXTERNAL DRIVE SELECT ID

     SCSI ID             JP1/6              JP1/7             JP1/9

           0             Open               Open               Open

          1             Open               Open              Closed

           2             Open              Closed              Open

           3             Open              Closed             Closed

           4            Closed              Open               Open

           5            Closed              Open              Closed

           6            Closed             Closed              Open

                         INTERNAL DRIVE SELECT ID

      SCSI ID             SW1/1             SW1/2             SW1/3

           0               Off               Off               Off

          1               On                Off               Off

           2               Off               On                Off

           3               On                On                Off

           4               Off               Off                On

           5               On                Off                On

           6               Off               On                 On

     MISCELLANEOUS TECHNICAL NOTES

  SW1 settings override JP1 settings.